Effect of Sealing Gas Washer Design on a PEM Stack Fuel Cell Performance
Minou Gholami Jourshari * , Mohammad Reza Ashraf Khorasani , Isar Dashti , Saeed Asghari , Hadi Goorabi , Saeed Golshah
Iran Renewable Energy Organization , minoo_gholami@yahoo.com
Abstract:   (2457 Views)

In this paper we study the performance of a PEM stack fuel cell after 900 hours of operation. We tried to identify any voltage degradation and its causes. Microscopic cracks on some parts of MEA mainly due to uniformity of pressure, stress concentration and elongation of membrane in the edge of GDL has been identified as the most important cause of this gradual degradation. High contact resistance between layers of stack, including the membrane, is another cause of PEM stack degradation. All problems are solved and tested by Electrochemical Impedance Spectrometry and the best amount of thickness of the membrane is determined. The result of EIS test with optimized sealing washer shows that the stack operation was optimized with the decrease of contact resistance in the several layers of stack in the active area of membrane.

Keywords: Fuel cell, 4 cells stack, EIS Test, MEA, Sealing washer
Full-Text [PDF 792 kb]   (531 Downloads)    
Type of Study: Research | Subject: Renewable Energy Technologies
Received: 2016/12/11 | Accepted: 2019/07/12 | Published: 2019/07/12
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Gholami Jourshari M, Ashraf Khorasani M R, Dashti I, Asghari S, Goorabi H, Golshah S. Effect of Sealing Gas Washer Design on a PEM Stack Fuel Cell Performance. IJE 2018; 21 (2) :120-111
URL: http://necjournals.ir/article-1-1175-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 21, Issue 2 (7-2018) Back to browse issues page
نشریه انرژی ایران Iranian Journal of Energy
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4645