<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Energy</title>
<title_fa>نشریه انرژی ایران</title_fa>
<short_title>IJE</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://necjournals.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1028-3706</journal_id_issn>
<journal_id_issn_online>2322-1240</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1398</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>22</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تخمین حجم آب برداشتی الکتروپمپ‌ها از طریق پارامترهای مصرف انرژی و ارتفاع پمپاژ چاه (مطالعه موردی:استان خراسان جنوبی)</title_fa>
	<title>Estimation of the Discharge of wells Electro-pump through Energy Consumption and Pumping Head Parameters (Case Study: South Khorasan Province, Iran)</title>
	<subject_fa>انرژی و محیط زیست</subject_fa>
	<subject>Energy and Environment</subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;span dir=&quot;RTL&quot;&gt;مدیریت برداشت از منابع آبی در سراسر جهان مستلزم بکارگیری روشها و ابزارآلات اندازه&#8204;گیری و نیروی انسانی است که&amp;nbsp; هزینه&#8204;ی بالایی را به بدنه حکمرانی منابع آب تحمیل می&#8204;کند. هدف این مقاله ارایه روشی است که بتواند بدون دخالت نیروی انسانی و بکارگیری تجهیزات اندازه&amp;shy;گیری، تخمین مناسبی از برداشت آب چاه&amp;shy;ها ارایه نماید. بدین منظور 38 حلقه چاه نمونه با شرایط مناسب (و با دسته&amp;shy;بندی&amp;shy;های مختلف از نظر ارتفاع پمپاژ) در استان خراسان جنوبی انتخاب شد. در این تحقیق با ثبت مقادیر برداشت حجم آب توسط الکتروپمپ و مقادیر مصرف انرژی پمپ (در طول یک بازه زمانی یکسان) و در نهایت برازش آماری آنها برای چاه&amp;shy;های انتخابی، یک ارتباط ریاضی برای تخمین حجم برداشت در یک باند خطای اطمینان مناسب بدست آمد.&amp;nbsp; با بکارگیری این رابطه، می&amp;shy;توان هزینه&#8204;های انسانی و تجهیزاتی برای کنترل تخلیه چاه&amp;shy;های آب را به حداقل ممکن رساند و یا تداوم کنترل بهره&amp;shy;برداری از چاه را در صورت خرابی یا عدم وجود تجهیزات اندازه&amp;shy;گیری با افزایش قابلیت اطمینان سیستم تضمین نمود. رابطه&#8204; پیشنهادی بر روی 162 چاه (با انتخاب تصادفی در همان استان) مورد ارزیابی قرار گرفت که نتایج نشان می&amp;shy;دهد خطای این رابطه با منظور کردن تمامی عوامل بیرونی دخیل، نسبت به مقادیر اندازه&amp;shy;گیری شده توسط کنتور آب بین 5 تا &lt;/span&gt;&amp;nbsp;&lt;span dir=&quot;RTL&quot;&gt;19.8&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;درصد است. معیار کارایی ضریب همبستگی (&lt;/span&gt;R&lt;span dir=&quot;RTL&quot;&gt;) که برای ارزیابی رابطه پیشنهادی استفاده شد، برای داده&amp;shy;های تحت آموزش 0.89 و برای داده&amp;shy;های تحت ارزیابی حدود 0.802 بدست آمد.&lt;/span&gt;</abstract_fa>
	<abstract>For managing the discharge of water resource, utilizing high precision measuring instruments and workers is necessary that can be lead to high cost on the governments. The purpose of this paper is to present a new approach that can provide a good estimation of the well water discharge without human intervention and the use of measuring equipment. In this research, 38 wells with suitable conditions (with different categories of pumping head) were selected in South Khorasan province, Iran. Then a mathematical equation for estimating the well water discharge in a confidence interval was obtained and developed by recording the data of water discharge and the energy consumption of the pump (during a time interval) and finally fitting them statistically to the selected wells. This new approach is beneficial to minimize human and equipment costs to control the discharge of water wells. This approach can be as a suitable and alternative method that guarantees the reliability of the system in some cases such as crashing the measuring equipment and etc.&amp;nbsp; The Proposed equation was verified on 162 wells (randomly selected in mentioned province) and according to the results, the error of this equation by considering all external error factors is between 5 % and 19.8% compared to the values measured by the water meter&lt;span dir=&quot;RTL&quot;&gt;.&lt;/span&gt; The efficiency criteria of correlation coefficient (R) applied to evaluate the proposed equation for training and testing data was 0.89 and 0.802 respectively.</abstract>
	<keyword_fa>کنترل برداشت آب, مصرف انرژی الکتروپمپ, منابع انرژی یارانه ای, ارتفاع پمپاژ, تخلیه آبخوان, کنتور آب, حجم برداشت آب</keyword_fa>
	<keyword>Control of water discharge,  Power consumption of electro-pump,  subsidized energy resources,  Pumping head, Aquifer Discharge, Water meter, Water discharge,</keyword>
	<start_page>109</start_page>
	<end_page>126</end_page>
	<web_url>http://necjournals.ir/browse.php?a_code=A-10-2100-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>mohamad</first_name>
	<middle_name></middle_name>
	<last_name>Hasan-Sagha</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسن سقا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hasansaqa@gmail.com</email>
	<code>10031947532846005291</code>
	<orcid>10031947532846005291</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>IWRM</affiliation>
	<affiliation_fa>شرکت مدیریت منابع آب ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
