IJE 2008, 11(1): 1-16 Back to browse issues page
Determining the Maximum Capacity of Distributed Generation for Maintaining the Recloser-Fuse Coordination in Distribution Systems
A Farzanehrafat * , AM Javadian , MR Haghifam , MT Bathaee
Abstract:   (11429 Views)
Traditional electric distribution systems are radial in nature, and are supplied through a main source. These networks have a very simple protection system, and its implementation is also very simple. Distributed generation (DG) is defined as energy sources connected to distribution systems. Presence of such energy resources in distribution systems is being extended rapidly because of its useful advantages, but such advantages can be achieved if the relevant concerns are deliberately taken into account. For example, penetration of DG currents results is not having a radial distribution network, and consequently losing protection coordination. This paper has analyzed and derived a set of equations of general characteristics of protection devices to represent such protection coordination and operating range constraints. This new approach is presented for determining the maximum capacity of distributed generation for maintaining the protection coordination. The proposed approach was implemented using MATLAB and Power Factory DIgSILENT on a simple distribution network and the numerical results is presented.
Keywords: Distribution system, Distributed generation, Protection coordination, Recloser
Full-Text [PDF 361 kb]   (2387 Downloads)    
Type of Study: Research | Subject: Energy Planning Models
Received: 2011/11/24 | Published: 2008/04/15
Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Farzanehrafat A, Javadian A, Haghifam M, Bathaee M. Determining the Maximum Capacity of Distributed Generation for Maintaining the Recloser-Fuse Coordination in Distribution Systems. IJE 2008; 11 (1) :1-16
URL: http://necjournals.ir/article-1-75-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 11, Issue 1 (Spring 2008) Back to browse issues page
نشریه انرژی ایران Iranian Journal of Energy
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4645