<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Energy</title>
<title_fa>نشریه انرژی ایران</title_fa>
<short_title>IJE</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://necjournals.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1028-3706</journal_id_issn>
<journal_id_issn_online>2322-1240</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1388</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2010</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>فرآیند تصمیم گیری برای تعیین اقتصادی مشخصات سیستم مبدل انرژی بادی در چهار منطقه متمایز ایران</title_fa>
	<title>Deciding Process of Economically Defining Wind Energy Conversion System Properties in Four Different Regions in Iran</title>
	<subject_fa>مدل هاي برنامه ريزي انرژی</subject_fa>
	<subject>Energy Planning Models</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=text-align: justify direction: rtl&gt;  در این مقاله، به بررسی نقش پارامترهای تاثیرگذار در تعیین خصوصیات سیستم تبدیل انرژی باد برای بهره برداری از توربین های بادی کوچک در جهت برآورده سازی تقاضا در بخش خانگی، پرداخته شده است. به طور کلی، تمامی عوامل تاثیرگذار بر سیستم تبدیل انرژی باد به دو دسته عوامل تعیین کننده خصوصیات توربین و همچنین شرایط جغرافیایی محل نصب توربین تقسیم بندی می شوند. از آنجا که انتخاب این سیستم برای مصرف کننده از نظر هزینه واحد برق تولید شده توسط توربین اهمیت زیادی دارد، در این مقاله روابط ریاضی بین دو فاکتور قطر روتور، ارتفاع پایه توربین و هزینه واحد برق تولید شده توسط توربین تعیین شده است. این دو فاکتور به عنوان دو فاکتور اصلی متاثر از فاکتورهای متعدد دیگر، به ترتیب مرتبط با خصوصیات توربین و شرایط جغرافیایی محل هستند. برای بررسی تاثیر هر کدام از دو فاکتور فوق و همچنین افزایش دقت محاسبات انجام گرفته، از توربین های با توان های مختلف و همچنین ارتفاع های مختلف پایه برای هر توربین در چهار منطقه با شرایط جغرافیایی متفاوت، از بین مناطقی که سهم بیشتری از پتانسیل انرژی باد کشور را پوشش می دهند، استفاده شده است. با در دست داشتن میزان درآمد خانوار و به دنبال آن مقدار هزینه پرداختی از سوی خانوار به ازای هر کیلووات ساعت مصرف برق، می توان با استفاده از این روابط به راحتی مشخصات سیستم تبدیل انرژی باد را تعیین نمود. لذا، به دلیل نقش مهمی که این روابط می توانند در تعیین خصوصیات سیستم تبدیل انرژی باد ایفا کنند، پیشنهاد می شود در تحقیقات آتی در این راستا، از آنها استفاده گردد. &lt;/div&gt;</abstract_fa>
	<abstract>This paper presents a deciding process for choosing the most adoptable wind energy conversion system in for regions in the country in Iran. The paper explains the trend during which the consumer can choose the system which is economically acceptable by knowing consumption needs and their living region, examining the influences of parameters affecting properties of small wind turbines, namely rated power and the hub height, to satisfy the power needs in household sector. Factors affecting wind energy conversion systems are categorized into two sets, family conditions (consumption needs) and geographical circumstances (installation position of the turbine). Since choosing this system is highly important for consumer, from the viewpoint of cost per unit of produced power by the turbine, in this paper mathematical relations between the two factors rotor diameter and turbine hub height, resulting from consuming power and geographical circumstances of the region respectively, are determined and then the cost per unit is estimated. Examining the influence of each of the above factors and increasing the validity of the results, turbines with different rated powers and different hub heights for each, in four regions with different geographical circumstances, among those having the greater share in wind energy potential of the country in cold and hot regions are used. Having family incoming rate and as the following the volume of costs paid by the family per 1 kWh of electricity consumption, wind energy conversion system properties can be conveniently specified using these relations.</abstract>
	<keyword_fa>سیستم تبدیل انرژی باد، ارزیابی پتانسیل انرژی باد، انرژی های تجدیدپذیر</keyword_fa>
	<keyword>Wind Resource Assessment, Renewable Energies, Wind Energy Conversion System.</keyword>
	<start_page>25</start_page>
	<end_page>40</end_page>
	<web_url>http://necjournals.ir/browse.php?a_code=A-10-2-17&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>A</first_name>
	<middle_name></middle_name>
	<last_name>Hatami</last_name>
	<suffix></suffix>
	<first_name_fa>آرش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حاتمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ahatami@ut.ac.ir</email>
	<code>1003194753284600550</code>
	<orcid>1003194753284600550</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>H</first_name>
	<middle_name></middle_name>
	<last_name>Shakouri Ganjavi </last_name>
	<suffix></suffix>
	<first_name_fa>حامد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شکوری گنجوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hshakouri@ut.ac.ir</email>
	<code>1003194753284600551</code>
	<orcid>1003194753284600551</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
