Classification of Energy Consumption of Lighting System in Buildings: a New Method
Sajjad Saedi , Javad Gholami , Masoud Alilou *
Urmia University , m.alilou@urmia.ac.com
Abstract:   (2198 Views)
In this research, a computational method for labeling a building lighting system is presented. In order to label the building lighting system, firstly, the light intensity of different spaces of the building is modeled using the lumen method based on the space index. Then, the building light energy ratio index is modeled according to the light intensity ratio of the studied building to the standard building light intensity. In order to make the proposed method more practical, temporal and spatial parameters are also considered in the relation of building light energy ratio. In other words, the light energy ratio of the building is modeled by considering the energy consumption during the day, energy consumption during the night, the duration of sunlight availability on different days of the year, weather conditions, and the area of ​​different building spaces. Finally, by implementing the light energy ratio of the building and show how to calculate its various parameters, the energy classification of the building lighting system is presented using the energy classes A+++ to G. According to the results of the project and the proposed classification, if the energy consumption of the lighting system of a building is maximumly 10 percent more than the energy consumption of the lighting system of the standard building, it has the competence to get the energy label A.
Keywords: Lighting system label, Energy class A, Lumen method based on space index, Weather conditions, Building lighting energy ratio
Full-Text [PDF 677 kb]   (1293 Downloads)    
Type of Study: Research | Subject: Energy Management, Conservation and Rational Use of Energy
Received: 2021/07/1 | Accepted: 2021/07/18 | Published: 2021/09/21
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Saedi S, Gholami J, Alilou M. Classification of Energy Consumption of Lighting System in Buildings: a New Method. IJE 2021; 24 (2) :7-33
URL: http://necjournals.ir/article-1-1681-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 24, Issue 2 (8-2021) Back to browse issues page
نشریه انرژی ایران Iranian Journal of Energy
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4645