:: Volume 20, Issue 4 (3-2018) ::
IJE 2018, 20(4): 113-131 Back to browse issues page
Energy Saving due to Combination of Atriums and Green Roofs: Case of a College Dormitory under Different Climatic Conditions
Seyed Alireza Zolfaghari * , Mohammad Amin Dashti
University of Birjand , zolfaghari@birjand.ac.ir
Abstract:   (2978 Views)
In the present study, the effect of simultaneous utilizing of atrium and green roof on the energy consumption of a college dormitory has been evaluated under three different climatic conditions of Iran, including Tehran, Tabriz, and Bandar Abbas. Therefore, four different construction designs on the basis of using atrium and green roof has been considerd for a college dormitory. Results indicate that only in the cold climate of Tabriz, the atrium could decrease the annular energy consumption. However, the atrium may cause to increase the annual load in Bandar Abbas. On the other hand, the results show that the green roof technology demonstrates the best performance in hot climate of Bandar Abbas with aboat 8% reduction in annual energy consumption. However, the green roof can cause the annual energy consumption to decrease about 7% and 3% in Tehran and Tabriz climatic conditions, respectively.
Keywords: Green roof, Atrium, Energy consumption, Climatic conditions
Full-Text [PDF 722 kb]   (804 Downloads)    
Type of Study: Research | Subject: Energy Management, Conservation and Rational Use of Energy
Received: 2015/08/1 | Accepted: 2016/03/9 | Published: 2018/03/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zolfaghari S A, Dashti M A. Energy Saving due to Combination of Atriums and Green Roofs: Case of a College Dormitory under Different Climatic Conditions. IJE 2018; 20 (4) :113-131
URL: http://necjournals.ir/article-1-907-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 20, Issue 4 (3-2018) Back to browse issues page
نشریه انرژی ایران Iranian Journal of Energy
Persian site map - English site map - Created in 0.06 seconds with 39 queries by YEKTAWEB 4710