[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
The 9th International Energy Conference
..
:: Volume 27, Issue 4 (2-2025) ::
IJE 2025, 27(4): 1-21 Back to browse issues page
Analysis and investigation of the effect of Sfa, Scb, Sca and Dsa climates on the passive design of nearly zero energy buildings
Vahid Rezaee * , Mojtaba Masoumnezhad
Technical and Vocational University (TVU), Tehran, Iran , Vahidrezaee.136698@gmail.com
Abstract:   (20 Views)
Climate plays an role before building construction, which depends on geographical location of the building. Climatic parameters including sunlight, temperature, humidity, rainfall, and wind determine the general design and components of the building, which must be designed for each climate. In this article, different comfort conditions and architectural provisions were proposed for near-zero energy consumption buildings design in different climatic conditions of Iran according to the Köppen-Geiger method using passive methods. Based on Köppen-Geiger climate classification, the Iran climate is segmented to nine climates. Sfa, Scb, Sca and Dsa climates are important climatic groups of Iran, each one covers a large part of the country. Using the Köppen-Geiger method and some selected cities in Sfa, Scb, Sca and Dsa climates by Client Consult software with EPW format according to ASHRAE 55 standard method and PMV comfort model (predicted mean vote) the effect of climatic conditions on near-zero energy consumption buildings design were proposed. By importing the climate parameters file of the selected cities in the Climate Consultant software, output results including psychrometric chart, sun shading chart, wind wheel and other results were obtained. Moreover, parameters of passive architecture for near-zero energy consumption building design, such as the orientation of windows, floor covers, amount of passive solar heating hours and other parameters were investigated.
 
Keywords: Climate, Köppen-Geiger, zero energy consumption buildings, comfort, passive
Full-Text [PDF 3230 kb]   (9 Downloads)    
Type of Study: Research | Subject: Energy and Environment
Received: 2024/06/2 | Accepted: 2025/09/4 | Published: 2025/02/28
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

rezaee V, Masoumnezhad M. Analysis and investigation of the effect of Sfa, Scb, Sca and Dsa climates on the passive design of nearly zero energy buildings. IJE 2025; 27 (4) :1-21
URL: http://necjournals.ir/article-1-1905-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 27, Issue 4 (2-2025) Back to browse issues page
نشریه انرژی ایران Iranian Journal of Energy
Persian site map - English site map - Created in 0.07 seconds with 39 queries by YEKTAWEB 4718