Development of an Optimized BMS Model Utilizing Energy Consumption Simulation in Tehran
Bahareh Najm , Samira Ghiasi * , Mohammadreza Vafaei
, Sghiasi92@gmail.com
Abstract:   (57 Views)
Nowadays, buildings exhibit high energy wastage, and due to their heavy reliance on fossil fuels, the adoption of intelligent management systems presents a viable solution. These systems can not only reduce energy consumption but also mitigate the waste of fossil fuels. Therefore, the aim of this study is to investigate the impact of a Building Management System (BMS) utilizing an energy consumption simulator to enhance the energy efficiency of buildings. This research employs an experimental simulation method using the DesignBuilder software. In this study, a three-story building with one basement floor was initially designed in DesignBuilder, located in the Mehrabad Airport area of Tehran. The energy loss through the building’s external walls was then examined based on the software's default data. The results indicated that modifications in the wall design, consisting of five layers from outside to inside: 20 cm thick travertine stone, 20 cm thick Silicafom cement, 10 cm thick brick blocks, 8 cm thick polystyrene insulation, and 1.3 cm thick plaster layer, reduced the energy loss from the walls by 46.3 kW. Additionally, the use of electrochromic smart glass reduced energy loss from 8.5 kW to 4.76 kW compared to conventional glass. Therefore, it can be concluded that by utilizing smart materials in a three-story building, the total energy loss in the studied building decreased from 233.48 kWh to 81.15 kWh.
 
Keywords: BMS, Smart Glass, Smart Materials, Silicafom Cement, Electrochromic Smart Glass
Full-Text [PDF 715 kb]   (16 Downloads)    
Type of Study: Research | Subject: Energy Management, Conservation and Rational Use of Energy
Received: 2025/03/5 | Accepted: 2025/07/19 | Published: 2024/08/31
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Najm B, Ghiasi S, Vafaei M. Development of an Optimized BMS Model Utilizing Energy Consumption Simulation in Tehran. IJE 2024; 27 (2) :51-66
URL: http://necjournals.ir/article-1-1942-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 27, Issue 2 (8-2024) Back to browse issues page
نشریه انرژی ایران Iranian Journal of Energy
Persian site map - English site map - Created in 0.07 seconds with 39 queries by YEKTAWEB 4714