Optimal Design of a 100kw Grid Connected Photovoltaic Power Plant In Tehran Using Pvsyst Software
Mohammad Hossein Shams * , Mohsen Kia , Behdad Mahdavi
, mhshams@alum.sharif.edu
Abstract:   (10228 Views)
This paper presents a practical and operational aspects of optimal sizing of equipments in a 100 kW grid connected photovoltaic power plant. PV modules and inverters are the main elements of PV power plants and optimal selection of capacity and configuration of them will cause in increase of output energy. Photovoltaic modules in the design, arrangement and number of strings in the array are specified. Also proposed method describes how to select the inverter and also how to select the optimal configuration of the various configurations. The deployment of arrays of photovoltaic power plants in the field, with the space between the rows mentioned obeying occupy less area for ease of maintenance and prevention of photovoltaic modules shading effects. Also according to the latitude of Tehran, the optimum slope of photovoltaic modules is determined in terms of design. Finally, the proposed design and calculations verified by PVSyst simulation software.
Keywords: Photovoltaic power plant, Module, inverter, configuration of elements
Full-Text [PDF 1889 kb]   (3852 Downloads)    
Type of Study: Research | Subject: Energy Planning Models
Received: 2013/08/6 | Published: 2013/07/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shams M H, Kia M, Mahdavi B. Optimal Design of a 100kw Grid Connected Photovoltaic Power Plant In Tehran Using Pvsyst Software. IJE 2013; 16 (2)
URL: http://necjournals.ir/article-1-481-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 16, Issue 2 (7-2013) Back to browse issues page
نشریه انرژی ایران Iranian Journal of Energy
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4710